Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Still deciding? Get samples of US$ 1/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product model: PVC single core solid insulated wire / BV Wire / H07V-U
Number of cores: 1 core
Product specifications: 1.5-400mm²,
Product colour: Red, yellow, blue, green, black; other colors can be customized.
Rated voltage: 450/750V
The length of the whole plate: 90/95/100m (national standard full meter).
---------------------------------------------------------
---------------------------------------------------------
Product model:PVC insulated single core flexible wire / BVR / H07V-K
Number of cores: 1 core
Product specifications: 1.0-35mm²
Product colour: Red, yellow, blue, green, black, brown ; other colors can be customized
Rated voltage: 450/750V
The length of the whole plate: 90/95/100m (national standard full meter)
Use characteristics: the long-term allowable working temperature of the cable core should not exceed 70ºC, BV-90 type should not exceed 90ºC, the short-term working temperature can be raised to 105ºC, the laying temperature of the cable should not be lower than 0ºC.
Allowable bending radius: when the cable outer diameter (D) is less than 25mm, the allowable bending radius of the cable should be not less than 4D; when the cable outer diameter (D) is 25mm and above, the allowable bending radius of the cable should be not less than 6D.
Nominal section mm² |
No. of Strands #/mm |
Insulation Thickness mm |
Overall Jacket Thickness mm |
Approx. Wt. kg/km |
Minimum insulation resistance at 70°C Ω·km |
1.5 | 1/1.38 | 0.7 | 3.3 | 20.3 | 11.0 |
7/0.52 | 0.7 | 3.5 | 21.6 | 10.0 | |
2.5 | 1/1.78 | 0.8 | 3.9 | 31.6 | 10.0 |
7/0.68 | 0.8 | 4.2 | 34.8 | 9.0 | |
4 | 1/2.25 | 0.8 | 4.4 | 47.1 | 8.5 |
7/0.85 | 0.8 | 4.8 | 50.3 | 7.7 | |
6 | 1/2.76 | 0.8 | 4.9 | 65 | 7.0 |
7/1.04 | 0.8 | 5.4 | 71.2 | 6.5 | |
10 | 7/1.35 | 1.0 | 7.0 | 119 | 6.5 |
16 | 7/1.70 | 1.0 | 8.0 | 179 | 5.0 |
25 | 7/2.14 | 1.2 | 10.0 | 281 | 5.0 |
35 | 7/2.52 | 1.2 | 11.5 | 381 | 4.0 |
50 | 19/1.78 | 1.4 | 13.0 | 521 | 4.5 |
70 | 19/2.14 | 1.4 | 15.0 | 734 | 3.5 |
95 | 19/2.52 | 1.6 | 17.5 | 962 | 3.5 |
120 | 37/2.03 | 1.6 | 19.0 | 1180 | 3.2 |
150 | 37*2.25 | 1.8 | 21.0 | 1470 | 3.2 |
185 | 37*2.52 | 2.0 | 23.5 | 1810 | 3.2 |
240 | 61*252 | 2.2 | 26.5 | 2350 | 3.2 |
Flexible Wire Parameters | |||||
Specification | BVR 1.5mm² | BVR 2.5mm² | BVR 4.0mm² | BVR 6.0mm² | BVR 10mm² |
Conductor diameter | 0.52MM (±0.01) |
0.41MM (±0.01) |
0.52MM (±0.01) |
0.64MM (±0.01) |
0.52MM (±0.01) |
Number of copper wires | 7 conductors | 19 conductors | 19 conductors | 19 conductors | 49 conductors |
Average outside diameter | 2.7-3.3mm | 3.3-4.0mm | 3.8-4.6mm | 4.3-5.2mm | 5.6-6.7mm |
Extreme power | 4180W | 5720W | 7700W | 9680W | 13200W |
Nominal section mm² |
No. of Strands No./Dia.(mm) |
Insulation Thickness mm |
Overall Jacket Thickness mm |
Approx. Wt. kg/km |
Minimum insulation resistance at 70°C Ω·km |
H05V-K | |||||
0.5 | 16/0.2 | 0.6 | 2.6 | 9.1 | 12 |
0.75 | 24/0.2 | 0.6 | 2.8 | 12.2 | 10 |
1.0 | 32/0.2 | 0.6 | 3.0 | 15.1 | 10 |
H07V-K | |||||
1.5 | 30/0.25 | 0.7 | 3.5 | 21.4 | 10 |
2.5 | 49/0.25 | 0.8 | 4.2 | 24.5 | 9.0 |
4 | 56/0.30 | 0.8 | 4.8 | 51.8 | 7.0 |
6 | 84/0.30 | 0.8 | 6.4 | 74.1 | 6.7 |
10 | 80/0.40 | 1.0 | 8.0 | 120 | 5.6 |
16 | 126/0.40 | 1.0 | 8.8 | 211 | 4.6 |
25 | 196/0.40 | 1.2 | 11.0 | 303 | 4.4 |
35 | 276/0.40 | 1.2 | 12.5 | 417 | 3.8 |
H07V-R is single core cable and a type of low voltage house wiring cable, which is often used in houses, offices, electrical control panels, and industrial lighting. The conductor is pure copper and the high-quality PVC insulation to protect the copper core from external damage will increase the service life of wires and cables.
1. Pure copper conductor, the use of pot technology to eliminate internal stress, avoiding unevenness at both ends caused by continuous pulling and retreating, has good electrical conductivity and safety.
2. The environmentally-friendly PVC raw material, good insulation performance, scratch resistance, abrasion resistance, good toughness.
3. The low eccentricity of the wire and cable, the uniform insulation prevents the cable from breaking down and ensures the safety of electricity.
The product is suitable for fixed installation of power plant with rated AC voltage up to and including 450/750V. Such as home decoration lighting. Fixed wiring can be used for indoor open coating, pipe piercing and other occasions. In order to facilitate the difference in the installation process, it can be divided into seven colors: red, yellow, blue, green, black, white and double. As BVR is soft structure, its application scope is mostly in soft environment.
The only difference between BVR wire and BV wire is that the diameter of the R wire conductor is soft copper wire. That is, increase the number of conductors and reduce the diameter of a single conductor. The diameter of a single conductor is less than 1 mm. In this way, BVR wire is very soft, laying Angle requirements are greatly reduced than BV wire, threading pipe, groove more convenient, fast, reduce the working intensity while greatly improving the work efficiency. By the majority of electricians and architectural decoration personnel like!