Type |
Name |
Section Area (mm2) |
No.of Core |
Application Site |
KVV |
CopperConductor,PVC Insulated and Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
10 |
2-10 |
KVVP |
Copper Conductor, |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors, |
PVC Insulated and Sheathed, |
4 6 |
2-14 |
in cable ditches or pipes where shielding is required |
Braiding Shielded Control Cable |
10 |
2-10 |
|
KVVP2 |
Copper Conductor, |
0.75 1.0 1.5 2.5 |
4-10 |
Permanent installation indoors, |
PVC Insulated and Sheathed,Copper-tape Screened Control Cable |
4 6 |
7-61 |
in cable ditches or pipes where shielding is required |
|
10 |
4-10 |
|
KVV22 |
Copper Conductor, |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches, |
PVC Insulated and Sheathed,Steel tape Armored Control Cable |
4 6 |
4-14 |
Be able to withstand stronger external mechanical force |
|
10 |
4-14 |
|
KVVR |
Copper Conductor, |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
PVC Insulated and Sheathed,Flexible Control Cable |
KVVRP |
Copper Conductor, |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
PVC Insulated and Sheathed, |
Braiding shielded Flexible Control Cable |
1.5 2.5 |
4-48 |
KYJV |
CopperConductor, |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
XLPE Insulated and PVC Sheathed Control Cable |
4 6 |
2-14 |
|
10 |
2-10 |
KYJVP |
Copper Conductor, |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches |
XLPE Insulated,Braiding Shielded, |
4 6 |
2-14 |
or pipes where shielding is required |
PVC Sheathed Control Cable |
10 |
2-10 |
|
|
CopperConductor,XLPE Insulated,Steel-tape Armoured, |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches, |
KYJV22 |
PVCSheathed Control Cable |
4 6 |
4-14 |
pipes or underground Be cable to with stand stronger external mechanical force |
|
|
10 |
4-10 |
|
KYJVP2 |
CopperConductor,XLPE Insulated,Copper tape Screened, |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors, |
PVCSheathed Control Cable |
4 6 |
4-14 |
in cable ditches or pipes where shielding is required |
|
10 |
4-10 |
|
KYJVR |
CopperConductor,XLPE Insulated, |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
PVCSheathed Flexible Control Cable |
KYJVRP |
CopperConductor,XLPE Insulated,Braiding Shielded, |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
PVC Sheathed Flexible Control Cable |
1.5 2.5 |
4-48 |