Product parameters
Product model: XLPE insulated PE sheathed copper core low voltage power cable
Number of product cores: 1-5 cores
Product specifications: 1.5mm²--500mm²
Product colour: red, yellow, blue, green, black; other colours can be customized
Rated voltage: 0.6/1KV
The length of the whole plate: 100m (national standard full meter)
Maximum conductor temperature during normal operation: 90°C for PE insulation, 90°C for XLPE insulation.
Installation and laying temperature: The installation and laying temperature of the cable should be not lower than 0C.
Maximum temperature of the cable conductor during short circuit (maximum duration not exceeding 5 seconds): PVC insulation - 160°C for conductor cross-section ≤ 300 mm2, 140°C for conductor cross-section > 300 mm2; 250°C for XLPE insulation.
Scope of application: This product is suitable for use in lines with an AC rated voltage U0/U of 0.6/1kV for transmission and distribution lines.
Minimum bending radius allowed: Single-core cable: 20D without armour, 15D with armour Multi-core cable: 15D without armour, 12D with armour Where: D - actual outer diameter of the cable.
Type | Description | Applicable scope | |
Cu | Al | ||
YJV | YJLV | Cu or Al conductor XLPE insulated PVC sheathed power cable | For laying indoor and outdoor, unable to bearextemal mechanical force but the tractive forceduring laying. Laying single core cable inmagnetic duct is not permissible. |
YJY | YJLY | Cu or Al conductor XLPE insulated PE sheathed power cable | |
YJV22 | YJLV22 | Cu or Al conductor XLPE insulated steel tape armored PVC sheathed power cable | For laying underground, able to bear externalmechanical force, but unable to bear largepulling force. |
YJV23 | YJLV23 | Cu or Al conductor XLPE insulated steel tape armored PE sheathed power cable | |
YJV32 | YJLV32 | Cu or Al conductor XLPE insulated steel wire armored PVC sheathed power cable | For laying underground along route withdifferent level, able to bear external mechanicalforce and moderate pulling force. |
YJV33 | YJLV33 | Cu or Al conductor XLPE insulated steel wire armored PE sheathed power cable | |
YJV42 | YJLV42 | Cu or Al conductor XLPE insulated thick steel wire armored PVC sheathedpower cable | |
YJV43 | YJLV43 | Cu or Al conductor XLPE insulated thick steel wire armored PE sheathed powercable |
Rated voltage 0.6/1kV insulated power cable is suitable for use in power systems of 1kV and below, and can be used in transmission systems and distribution systems as a carrier for power transmission.
Flame-retardant power cables have the characteristics of ordinary plastic power cables, but also have the characteristics of not easily catching fire or catching fire and delaying combustion only within a certain range, especially suitable for fire alarm, firefighting facilities, emergency evacuation and other fire emergency system distribution.
Halogen-free, low-smoke, flame-retardant power cables have the characteristics of ordinary plastic force cables and ordinary flame-retardant cables, but also have the characteristics of no halogen acid gas release when the cable is on fire, less smoke, less corrosive gas generation and good flame-retardant performance, etc. They are especially suitable for fire alarm, firefighting facilities, emergency evacuation and other fire emergency system distribution.